Table 1. Maximum Ratings
(Maximum ratings are the limits to which the device can be exposed without causing permanent damage.)
Rating
Powered Acceleration (all axes)
Unpowered Acceleration (all axes)
Supply Voltage
Drop Test (1)
Storage Temperature Range
Symbol
G pd
G upd
V DD
D drop
T stg
Value
1500
2000
–0.3 to +7.0
1.2
–40 to +125
Unit
g
g
V
m
°C
1. Dropped onto concrete surface from any axis.
ELECTRO STATIC DISCHARGE (ESD)
WARNING: This device is sensitive to electrostatic
discharge.
Although the accelerometers contain internal 2 kV ESD
protection circuitry, extra precaution must be taken by the
user to protect the chip from ESD. A charge of over 2000 volts
can accumulate on the human body or associated test
performance or cause failure of the chip. When handling the
accelerometer, proper ESD precautions should be followed
to avoid exposing the device to discharges which may be
detrimental to its performance.
equipment. A charge of this magnitude can alter the
MMA3202KEG
Sensors
2